Generelle spesifikasjoner | |
---|---|
Bruttovekt | N/A kg |
Produsentens varenummer | 80313 |
8-fold switched and metered PDU (Power Distribution Unit)
8031-1: 8x IEC C13 8031-2: 8x IEC C13 Lock
8031-3: 8x safety socket type F (DE) 8031-4: 8x type G (BS 1363, GB)
8031-6: 8x NEMA 5-15 (US)
Key Features
- Event and schedule controlled switching
- Precise current metering of up to 9 electrical units and residual current
- 2 connectors for plug-and-play sensors
- Simple and quick mounting due to integrated mounting straps
- NTP function can be activated
- Integrated overvoltage protection type 3
Switching function
- Each power port can be switched via HTTP(S), SNMP, ModbusTCP or command line interface via Telnet, SSH, MQTT and serial interface
- Programmable on/off sequences for remote reboots (Remote Reboot)
- Power ports can be switched when preset sensor thresholds are exceeded
- Self-healing function thanks to 8-channel watchdog: Each power port can be assigned its own Watchdog (ICMP/TCP), which initiates an automatic restart if necessary
- Switching state and switch-on delay up to 9999 seconds (166 minutes) individually adjustable for each output port after power failure
- Current peaks due to increased inrush currents are automatically prevented by sequential switch-on with a latency of 1 second
Go to demo webserver Go to product brief
Metering function
- Power consumption metering (kwH) with 2 energy counters: one counter counts consistently, the other counter is resettable
- Metering of current (A), voltage (V), phase angle, power factor, frequency (Hz), active power (W), apparent power (VA) and reactive power (VAr)
- Metering of differential current type A (mA) and type B (mA) upon request
- 2 connectors for combined plug-and-play sensors (temperature, humidity and air pressure) to prevent often occurring physical hazards like overheating and increased humidity or air pressure
Security
- Integrated type 3 overvoltage protection prevents damage to the device and connected loads
- Long-life High-Inrush Relays prevent welding of relay contacts during inrush current peaks
- Generation of status messages and alarms (e-mail, syslog, SNMP traps MQTT, SSH, Telnet)
- Encrypted e-mails (SSL, STARTTLS)
- Access protection by IP access control
- Encrypted communication through SSL (TLS 1.1, 1.2, 1.3) and SSH
- Password protected access
- Beeper for audible alarm when sensor limits are exceeded/deceeded
- IEC-Lock power ports prevent accidental unplugging of power cables (for EPC 8031-2)
Operation
- Easy-to-read LED display for displaying total current, IP address and sensor values
- Firmware update via Ethernet during operation (no restart required)
- Simple and flexible configuration via web browser, Windows or Linux program
- Dynamic assignment of an IP address via DHCP or manual assignment of static IP address
- Rapid commissioning thanks to free and reliable drivers from our technology partners